Digital I/O, 24 or 96 Lines, 5 V TTL/CMOS
379
National Instruments • Tel: (800) 433-3488 Fax: (512) 683-9300 [email protected] ni.com
Data Acquisition and
Signal Conditioning
Overview and Applications
NI 6503 devices are 24-bit parallel DIO interfaces for PCI, PCMCIA,
and ISA. NI 6508 devices offer 96-bit parallel DIO interfaces for PCI,
PXI, and ISA. All NI 650x devices are designed for 5 V TTL/CMOS
I/O signals.
Hardware
82C55 Parallel Port Interfaces
NI 650x devices use 82C55 Parallel Port Interfaces (PPIs). NI 6503
devices contain one PPI, and the NI 6508 devices contain four. Each
PPI controls 24 bits of DIO and has three 8-bit ports (A, B, and C). You
can configure each port as either input or output. Ports A and B are
always used for digital data I/O, while port C can be configured for
digital data I/O, control, status, or handshake signals.
Digital I/O Power-Up State Selection
You can power up the PCI-6503, PC-DIO-24, PC-DIO-96, and
PXI-6508 DIO lines in a user-defined state – either high or low. On
these devices, each line is connected to a 100 k resistor, and you can
use a jumper to select whether the lines of the device power up in
the high or low state. The DAQCard-DIO-24 and PCI-DIO-96 have
100 k resistors that always pull high.
Digital I/O Connector
Digital connectors for the NI 650x devices are described in Table 2.
The eight bits in Port A of each PPI are at xPA7 through xPA0 on the
digital I/O connector where x represents which PPI is being used. Ports B
and C are at xPB7 through xPB0 and xPC7 through xPC0, respectively.
Each port is programmed to be input or output. Power from the
computer I/O channel is also available on the DIO connector. See page
381 to learn more about connectivity solutions, including direct
connectors, electromechanical relay devices, and other signal
conditioning solutions.
24 or 96 digital input/output lines
•5 V TTL/CMOS
2-wire handshaking capability
•Known power-up states
NI-DAQ driver simplifies
configuration and measurements
Models
•NI PCI-6503
NI DAQCard-DIO-24
NI PC-DIO-24
NI PCI-DIO-96
NI PXI-6508
NI PC-DIO-96
Operating Systems
•Windows 2000/NT/XP
•Real-time performance with
LabVIEW (see page 134)
•Others such as Linux and
Mac OS X (see page 187)
Recommended Software
LabVIEW
LabWindows/CVI
•Measurement Studio
Other Compatible Software
•Visual Basic
C/C++, C#
Driver Software (included)
NI-DAQ 7
NI 650x
Family Bus Digital I/O Lines Device Type Logic Level Isolation Handshaking I/O 8255 Chipset Change Notification Pattern Matching
NI 6503 PCI 24 Software timed 5 V TTL/CMOS
1
PCMCIA
ISA
NI 6508 PCI 96 Software timed 5 V TTL/CMOS
1
PXI
1
ISA
1
Handshaking supplied by the 8255; only one handshaking mode is available.
Table 1. NI 650x Specifications Overview (See page 385 for detailed specifications.)
Device Connector
PCI-6503 50-pin, shown in Figure 3
PC-DIO-24
DAQCard-DIO-24 27-pin; cable adapts it to the 50-pin connector shown in Figure 3
NI 6508 100 pin; shown in Figure 2
24 or 96-Line Digital I/O
Table 2. NI 650x Connector Overview
Vue de la page 0
1 2 3 4 5 6 7 8 9

Résumé du contenu

Page 1 - Hardware

Digital I/O, 24 or 96 Lines, 5 V TTL/CMOS379National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comData Acquisition an

Page 2 - Ordering Information

NI PCI-6503 ...777690-01NI DAQCard-DIO-24...

Page 3 - Cables, Connector Blocks

Digital I/O Connectivity and Signal Conditioning381National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comDigital I/O

Page 4 - Accessories for Digital I/O

382National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comDigital I/O Accessories and CablesData Acquisition andSignal

Page 5 - RTSI Bus Cables

Digital I/O Accessories and Cables383National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comDigital I/O Accessories an

Page 6 - Ribbon Cables

384National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comData Acquisition andSignal ConditioningRibbon CablesR1005050

Page 7 - Digital I/O Overview

374National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comDigital I/O OverviewData Acquisition andSignal ConditioningD

Page 8

Digital I/O Overview375National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comDigital I/O OverviewData Acquisition and

Page 9

376National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comDigital I/O OverviewData Acquisition andSignal ConditioningD

Commentaires sur ces manuels

Pas de commentaire